Thermocouple alloy strip

  • Large image

Thermocouple wire and thermocouple strip for use at temperatures up to 1260°C. Tankii thermocouple wire and strip is supplied with bright or oxidized surface according to standard or special EMF requirements.

Thermocouple temperature range and tolerance

Type Standard Operating temperature range (°C) for {Long term/Short term} Grade Temperature range Tolerance
Type K GB/T2614 K 1200 / 1300 I -40~1100 ±1.5°C/±0.4%t
--- --- --- II -40~1300 ±2.5°C/±0.75%t
Type N GB/T17615 N 1200 / 1300 I -40~1100 ±1.5°C/±0.4%t
--- --- --- II -40~1300 ±2.5°C/±0.75%t
Type E GB/T4993 E 750 / 900 I -40~800 ±1.5°C/±0.4%t
--- --- --- II -40~900 ±2.5°C/±0.75%t
Type J GB/T4994 J 600 / 750 I 0~750 ±1.5°C/±0.4%t
--- --- --- II --- ±2.5°C/±0.75%t
Type T GB/T2903 T 300 / 350 I -40~350 ±0.5°C/±0.4%t
--- --- --- II --- ±1°C/±0.75%t
--- --- --- III -200~40 ±1°C/±1.5%t